Description
NERGY-01-DIN ENERGY METERS

The device monitors the total values energy (ΣkWh) of the three phases by metering ACRMS mains voltage and RMS mains current Current and Voltage transformer primer value can be adjustedwith the parameter menu. Our device is a cost-effective solution and has all the essential parameters, especially for automation firms working in the area of energy saving, mains analysing and product costanalysing. The device can be integrated into scale systems easily by using MODBUS-RTU with RS485port. With the data table(register table), every three phases – neutral voltages,phase-phase voltages,currents and neutral current, frequency, power factors, power factor distortion, import and export activepower, reactive power, active and reactive energy, amplitude and % value of voltages and currents ofeach odd harmonics from 3. to 31., and zero cross angles of three phases voltages and currentscan be monitored and analysed.
Technical Data
Connection |
3P&4W |
Active Power:P1,P2,P3 |
No |
Reactive Power:Q1,Q2,Q3 |
No |
PF1,PF2,PF3 |
No |
Imp-exp. Active Energy kWh |
1 class |
Imp-ex Reactive Energy kVARh |
2 class |
Demand ve Peak |
No |
Energy pulse output |
No |
RS485 – MODBUS RTU |
Ok |
Password protection |
Ok |
Ambient temperature |
-5 C….+50 C |
Storage temperature |
-20 C….+70 C |
Display |
LED Display |
Current Transformer |
X/5A |
Current transformer ratio |
1….5000 |
Voltage transformer ratio |
1….4000 |
Auxiliary supply voltage |
230 Vac <4VA |
Dimensions |
105x90x59 mm |
Quantity in 1 box |
12 |
PARAMETERS
: The device enters the parameter menu by pushing the SET button for 3 seconds. With the direction buttons, it is possible to go up and down along the parameter menu. After pushing the SET button, the value can be increased or decreased with the direction buttons. By pushing the direction buttons longer, the value increases or decreases faster. With the SET button, the adjusted value will be recorded in the memory
Current: Current Transformer Primer Value ( 5 …..10000 / 5A ) Current trend. primer value is adjusted. Ex: For 500 / 5A current trans. ,500 is entered. Voltage: Voltage Transformer Ratio ( 1 …..1000 ) If there is no voltage transformer, this value must be 1. This is also the factory default value. Device No: The device number can be adjusted between 1-255. Baud rate: 2400-4800-9600-19200-28800-38400-57600-115200 Parity: no-odd-even Stop Bit: 1 – 0.5 – 2 – 1.5 Clear: yes (clear), no (not clear) quit: quit from parameter menu